According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
Ada compliant bathroom door opening.
This applies to interior hinged doors and gates as well as sliding and folding doors.
Of force to open.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
The ada standards do not specify the opening force for exterior doors though some state and local building codes may have requirements.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
Doorways shall have a minimum clear opening of 32 in 815 mm with the door open 90 degrees measured between the face of the door and the opposite stop.
Ada compliance applies to every part of your building but the restroom can be especially tricky to get right when you compare its relatively small space to the number of objectives you re required to meet.
Most handicap doors swing out for more room in the compartment.
Doors cannot swing into required clear floor or ground spaces in these specific instances.
A 36 stall door is used most often with a wheel fitting through that opening.
Having an alcove stall which is surrounded by three walls require 60 diameter on the inside of the compartment.
Door hardware ada compliant locks exit devices handles pulls latches and other operable parts on doors shall comply operable parts of such hardware shall be 34 inches minimum and 48 inches maximum above the finish floor or ground.
The opening force of exterior swing doors is impacted by wind loading and other exterior conditions gasketing hvac systems energy efficiency and the weight of doors.
The minimum force needed to ensure proper closure and positive latch usually exceeds the accessible limit of 5 pounds of force lbf required at other doors.
Clear floor space at controls for automatic and power assisted doors and gates 404 3 5 fixture clearances in toilet and bathing facilities except those that are single user where wheelchair space beyond the door swing is provided 603 2 3.
Magic force our most versatile door opener this option can be configured upon installation to provide either full energy motion activated or low energy knowing act automation.
Examples of ada toilet stalls.
Interior accessible doors should require no more than 5 lbs.