Example single user toilet room.
Ada dimensions for toilet paper dispensers.
The bottom of the reflective mirror starts at 40 from the floor.
The mirrors must be ada approved and are tilted to help the handicap.
Non recessed dispenser location if the grab bar is 36 high a non recessed toilet paper dispenser located above the bar must have an outlet at exactly 48 high to accommodate both the max.
Roll dispensers are much better and more recommended than folded tissue dispensers since folded tissue dispensers require us to use our finger to pinch the tissue.
Hand dryer of paper towel dispenser 3.
18 inches to 20 inches 455 to 510mm 20 inches to 25 inches 510 to 635mm 25 inches to 27 inches 635 to 685mm toilet tissue dispenser height14 inches 355mm 14 inches to 17 inches 355 to 430mm 17 inches to 19 inches 430 to 485mm 5 door sfor interior use must push or pull open with a maximum of 5 pounds of force lbf 22 2 n.
Toilet paper dispensers shall comply with 309 4 and shall be 7 inches 180.
Look for dispensers that hold enough toilet tissue and deliver it in an easy to grab fashion.
Compliant ada dispenser heights and locations.
Look for sturdy easy to grip models.
However ansi allows for 6 mm projection in the allowed area.
Towel dispensers are mounted at 48 at the bottom of the dispenser from the floor.
Recessed dispensers are allowed within the 12 305 mm space above and 1 38 mm space below and at the end of a grab bar for ada the recessed dispenser must be flush.
3 the outlet of the toilet paper dispensers should not be mounted lower than 14 and no higher than 19 4 the top of the gripping surface at grab bars for children should be mounted between 18 27 a f f.
The ada emphasizes grab bars to maintain balance and prevent falls.
For ada and ansi nothing can be installed directly behind the grab bar.
The outlet of the dispenser shall be 14 inches 355 mm minimum and.
Mm minimum and 9 inches 230 mm maximum in front of the water closet measured to the.
19 inches 485 mm maximum above the finish floor.
Section 604 7 of the 2010 ada standards specify that the outlet of a toilet paper dispenser must be within a range of 15 inches to 48 inches above the finished floor.
Toilet tissue dispensers are at 15 19 from the floor.
Diaper changing stations 5.
Toilet paper dispenser 8.
Reach height and the 12 min.
Refer ada section 609 4 there is an advisory table which divides these ranges into ages.
Toilet seat cover dispenser 6.
Clearance above the grab bar.
Ideal ada bathroom dimensions especially for toilet paper holder is at least 485mm over your bathroom flooring.
Example of compliant heights to highest operable parts.
Access to the grab bars is an important feature to take into consideration when installing a toilet paper dispenser.
Also toilet tissue dispensers can t control delivery or limit paper flow.
Toilet grab gars.
This document is to be.