Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
Ada door clearance pull side.
48 inches 1220 mm 0 inches 0 mm 1.
The depth can be 54 min.
This is based on a new door installation or a door that is on an accessible route.
Front approaches to pull side of swinging doors shall have maneuvering space that extends from the hinge side of the door to 18 inches 455 mm minimum 24 inches 610 mm preferred beyond the latch side of the door and 60 inches 1525 mm minimum perpendicular to the doorway.
Pull side 44 push side min per cbc 60 24 per cbc 24 48 min 54 min min pull side push side.
Maneuvering clearances at doors.
Space at least 60 deep in front of a door will accommodate a forward approach except in case of hinge approaches on the pull side.
Depending on the direction of approach diagrams a through f illustrate minimum maneuvering space depths and latch side clearances for both push and pull sides of swinging sliding and folding doors.
Parallel to doorway beyond latch side unless noted from front.
60 inches 1525 mm 18 inches 455 mm from front.
On the pull side of hinge approaches 36 min.
404 2 4 1 swinging doors and gates swinging doors and gates shall have maneuvering clearances complying with table 404 2 4 1.
Door or gate side.
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
In a nutshell what this is saying is that the 18 minimum clearance required at the pull side of the door or the 12 on the push side of a door with a closer and a latch is not required if the door is recessed no more than 8.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
If the latch side clearance is at least 42.
Minimum maneuvering clearances at doors and gates shall comply with 404 2 4.
All doors in alcoves shall comply with the clearances for front approaches.
60 inches 1525 mm 36 inches 915 mm from hinge side.
Door clearances sources 26 ada sources 309 operable parts 404 2 manual doors doorways and manual gates 404 2 2 double leaf doors and gates.
If you approach a door from the latch side and will need to pull the door open the minimum clearance on the opening side perpendicular to the doorway is 48 inches to allow for the door to open leaving room for a disabled individual to move.
The maneuvering clearance at the door with a 36 door is then 48 x 60.
Latch approach pull side of door.
48 perpendicular to the doorway without closer 54 with closer but still have 24 parallel to doorway beyond latch.
On the parallel side beyond the latch is 24 inches should the door need to swing open.