602 2 clear floor space.
Ada drinking fountain height.
Elements such as wheelchair accessible drinking fountains must provide a knee clearance of at least 27.
If located to provide but not exceed this clearance 27 above the floor or ground absolute they are not protruding objects because the leading edge will be within cane detection.
4 15 drinking fountains and water coolers.
Drinking fountains or water coolers required to be accessible by 4 1 shall comply with 4 15.
They should also have a minimum clear floor space of 30 by 48 for wheelchair accommodation.
Drinking fountains drinking fountains that comply with ada regulations must be no taller than 36 inches as measured from the floor to the water spout.
Water coolers and bottle fillers can be provided at or integrated with compliant drinking fountains.
What makes a water fountain ada compliant.
The americans with disabilities act ada requires wall mounted drinking fountain units to have a clear knee space of at least 27 high 30 wide and 17 to 19 deep.
50 should be for wheelchair users adults and 50 should be for standing adults that can t bend down.
The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010.
To be ada compliant a drinking fountain must meet certain requirements.
The high drinking fountain must have the spout mounted 38 to 43 inches above the finished floor.
Knee and toe clearance complying with 306 shall be provided.
If a drinking fountain is provided a water cooler bottle filler or nearby sink cannot substitute for either the wheelchair accessible or the standing height drinking fountain in new construction additions or alterations.
Drinking fountains shall comply with 307 and 602.
Spout height and knee.
One thing to keep in mind when designing for children is that you still have to maintain the requirements for adults.
These regulations adopted revised enforceable accessibility standards called the 2010 ada standards for accessible design 2010 standards or standards.
Units shall have a clear floor or ground space complying with 305 positioned for a forward approach and centered on the unit.
The ada has height requirement provisions for counters tables and other articles where wheelchair use could impair a person s ability to effectively maneuver work and rest.
There are specific regulations related for knee clearance floor space in front of or beside the fountain spout location and height and location of the control.
The 2010 ada requires that a minimum of two drinking fountains be provided when drinking fountains are part of the project.
Spout height and knee clearance.
The usual request from tall people is the higher the better the building code now states there must be a minimum of two drinking fountains.