Vertical grab bars are not yet covered in the ada guidelines however ansi specifies the dimensions shown in the diagram.
Ada vertical grab bar requirements.
The icc a117 1 standard for accessible and usable buildings and facilities which is referenced by the international building code requires an 18 min.
Side wall the side wall grab bar shall be 42 inches 1065 mm long minimum located 12 inches 305 mm maximum.
Vertical grab bar requirements a vertical grab bar 18 455 mm minimum in length mounted along the side wall.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Grab bars need to be mounted lower for better leverage 33 36 840 915 mm high.
Grab bars in toilet stall requirements.
In figure 29 b a 42 inch 1065 mm minimum length grab bar is required to the side of the water closet spaced 12 inches 305 mm maximum from the back wall and extending a minimum of 54 inches 1370 mm from the back wall at a height between 33 and 36 inches 840 915 mm.
A summary of these requirements is below.
Towel sanitary napkins and waste receptacles max.
44 above the floor.
Ada grab bar requirements ada grab bar requirements for shower stalls bath tubs and toilet stalls consult manufacturer s installation instructions for proper installation of specific product.
Dimensions for grab bars.
Grab bars with non circular cross sections shall have a cross section dimension of 2 inches 51 mm maximum and a perimeter dimension of 4 inches 100 mm minimum and 4 8 inches 120 mm maximum.
The ada standards do not require this grab bar but allow a second grab bar to be within the 12 clearance above the horizontal grab bar 609 3 if there is a separation of 1 min.
Horizontal side wall grab bars need to be 42 1065 mm minimum length.
Each grab bar shall be installed 15 inches 380 mm maximum from the head end wall and 12 inches 305 mm maximum from the control end wall.
Vertical grab bar at water closets.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
14 from wall and 17 above floor with operable control at max.
Urinal min.
Grab bars 1 1 4 o 1 1 2 o mounted at 33 above floor with 1 1 2 wall clearance.
Center line of the bar located 39 990 mm minimum and 41 1040 mm maximum from the rear wall.
Toilets need to have horizontal bars behind and next to them and a vertical bar in front.
The space between the wall and the grab bar shall be 1 1 2 inches 38 mm.
Two grab bars shall be installed on the back wall one located in accordance with 609 4 and the other located 8 inches 205 mm minimum and 10 inches 255 mm maximum above the rim of the bathtub.
Bottom of the bar located 39 990 mm minimum and 41 1040 mm maximum above the floor.