The bar must be 1 1 4 to 1 1 2 inches in diameter.
Ada shower grab bar dimensions.
Must be minimum 60 x 30 from center points of opposing sides 60 minimum opening from top to bottom ansi calls for seat to be provided optional for ada folding seat placed on side wall no more than 3 from front entry back wall grab bar to extend 18 from.
Vertical grab bars are not yet covered in the ada guidelines however ansi specifies the dimensions shown in the diagram.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
They also must adhere to the following.
Grab bars in shower stall requirements transfer type shower compartments transfer type shower compartments shall be 36 inches 915 mm by 36 inches 915 mm clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch 915 mm wide minimum entry on the face of the shower compartment.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Grab bars in a shower should be mounted horizontally between 33 and 36 inches from the shower floor.
Grab bars in shower stall requirements transfer type shower compartments transfer type shower compartments shall be 36 inches 915 mm by 36 inches 915 mm clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch 915 mm wide minimum entry on the face of the shower compartment.
Dimensions for grab bars.
Or for answers to.
The controls shall be placed in an area between 38 48 inches 965 1220 mm above the floor.
The grab bar s shall be mounted 33 36 inches 840 915 mm above the shower floor measured at the entry.
The controls and spray unit shall be within 18 inches 455 mm of the front of the shower.
Grab bars in shower stall requirements transfer type shower compartments transfer type shower compartments shall be 36 inches 915 mm by 36 inches 915 mm clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch 915 mm wide minimum entry on the face of the shower compartment.
Horizontal side wall grab bars need to be 42 1065 mm minimum length.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
In a shower with a seat.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Ada standards for accessible design can be downloaded from www ada.
The rear wall grab bar shall be 36 inches 915 mm long minimum and extend from the centerline of the water closet 12 inches 305 mm minimum on one side and 24 inches 610 mm minimum on the other side.